<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-3223706315418806273</id><updated>2011-09-22T22:14:52.959-07:00</updated><title type='text'>Global Analyzer</title><subtitle type='html'></subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://global-analyzer.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>18</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-8365251666270726867</id><published>2010-02-07T06:28:00.000-08:00</published><updated>2010-02-07T06:33:10.828-08:00</updated><title type='text'>Gas Analyzer Series</title><content type='html'>Using an inovative dual gas filter correlation infrared for accuracy without cross interference, paramagnetic for O2, individual gas inputs, displays, outputs and ranges, the MGA9000 offers cost-effectiveness and performance.&lt;br /&gt;&lt;br /&gt;The gas analyzer has a totally automatic microprocessor-based operation including auto-startup, auto-calibration, auto-range, internal parameter monitoring and alarms. This makes the instrument ideal as a "smart" stand-alone unit or as a "building block" for systems integration via a RS-232 communications port or remote contact closures. Automatic diagnostics and fully-configurable concentration alarms are also integral to the series MGA9000 gas analyzers.&lt;br /&gt;&lt;br /&gt;A large multifunction, backlit LCD provides a clear display of carbon monoxide, carbon dioxide or sulfur dioxide gas concentration measurement, range, sample flowrate and the status of critical operating parameters including sample flow, pressure, temperature, DC and bias power supplies. The intuitive, menu-driven interface and soft key buttons enable the operator to quickly configure and control the gas analyzer function. The unit features 19" rack mounting at 3 RU height and a weight of 50 Lb. It has a dual voltage capability of 115 Vac and 230 Vac which is switchable from the rear panel.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-8365251666270726867?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/8365251666270726867'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/8365251666270726867'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2010/02/gas-analyzer-series.html' title='Gas Analyzer Series'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-2861213463562649490</id><published>2010-02-03T18:46:00.000-08:00</published><updated>2010-02-04T09:39:28.541-08:00</updated><title type='text'>Ohaus MB45 Moisture Analyzer</title><content type='html'>The Ohaus Moisture Analyzer (MB45) is the full featured, compact moisture analyzer for every budget! Perfect for environmental, quality control, food and beverage, chemical, pharmaceutical industries, and more, this fast, rugged analyzer gives you the flexibility you need and the accuracy you require for moisture determinations.&lt;br /&gt;&lt;br /&gt;The MB45 combines state-of-the-art heating with highly accurate weighing technology to deliver a faster, more precise method of moisture analysis.&lt;br /&gt;&lt;br /&gt;    * Fast halogen element provides uniform infrared heating up to 200 C&lt;br /&gt;    * Superior analytical performance, with readability of 1.0 mg, 0.01%moisture and 45 gram capacity&lt;br /&gt;    * Powerful software for ease of operation, program storage and user customization&lt;br /&gt;    * Heating at Light Speed&lt;br /&gt;    * Infrared halogen technology begins drying your sample in seconds. The unique gold reflective housing serves to create a more uniform distribution of heat, improving analyzer accuracy&lt;br /&gt;    * Precise Heating – software allows you to control temperature in 1 C increments, up to 200 C&lt;br /&gt;    * Lightning Start-Up – heat from 50 C to 180 C in less than 1 minute&lt;br /&gt;    * Rapid Results – infrared halogen heating performs up to 40%faster than traditional infrared methods.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-2861213463562649490?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/2861213463562649490'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/2861213463562649490'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/12/ohaus-mb45-moisture-analyzer.html' title='Ohaus MB45 Moisture Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-8168302460821699906</id><published>2010-02-03T07:00:00.000-08:00</published><updated>2010-02-03T07:13:55.726-08:00</updated><title type='text'>Automotive Emission Analyzer</title><content type='html'>NHA-501A f i v e - g a s Automotive Emission&lt;br /&gt;Analyzer is used to measure the concentration of HC,&lt;br /&gt;CO, CO2, NO and O2 contained in exhaust gases from gasoline vehicle engine. It is equipped with Chinese or English menu, LCD screen, automatic zeroing, automatic calculation and display of air fuel ratio . It can also make a comprehensive test for combustion and exhaust pollution. The instrument is assembled with imported key components and sensors by adopting advanced overseas technology. With the function of time and date display, 800 groups of data storage and review, RS-232C serial digital communication interface, it can be connected with external printer. The revolving speed can be tested under idling / dual idling speed with the supply of standard part inductive speed measuring pliers and optional part oil temperature probe accessories.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Main specification and technical parameter:&lt;br /&gt;Measuring range:&lt;br /&gt;HC: 0 to 10,000 ppm vol&lt;br /&gt;CO: 0 to 10 % vol&lt;br /&gt;CO : 0 to 18 % vol 2&lt;br /&gt;O : 0 to 23 % vol 2&lt;br /&gt;NO: 0 to 4,000 ppm vol&lt;br /&gt;&lt;br /&gt;Indication error:&lt;br /&gt;HC :&lt;br /&gt;Response time : less than 10s(for NO, less than 15s)&lt;br /&gt;Warm-up time: 30min&lt;br /&gt;Power source : AC 220V 10% 50Hz 1Hz&lt;br /&gt;Weight: 12kg&lt;br /&gt;&lt;br /&gt;Outer dimension:&lt;br /&gt;320mm(width) 200mm(height) 540mm(depth)&lt;br /&gt;0-2000 ppm vol:12 ppm vol (Absolute Error)&lt;br /&gt;or 5 % (Relative Error)&lt;br /&gt;2,001-9999 ppm vol: 10% (Relative Error)&lt;br /&gt;CO 0.06 % vol (Absolute Error) or 5 % (Relative Error)&lt;br /&gt;CO 0.5 % vol (Absolute Error) or 5 % (Relative Error) 2&lt;br /&gt;O 0.1 % vol (Absolute Error) or 5 % (Relative Error) 2&lt;br /&gt;NO 25 ppm vol (Absolute Error) or 4 % (Relative Error)&lt;br /&gt;(when the environmental temperature is not less&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-8168302460821699906?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/8168302460821699906'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/8168302460821699906'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2010/02/automotive-emission-analyzer.html' title='Automotive Emission Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-5238984854710167238</id><published>2010-01-28T04:48:00.000-08:00</published><updated>2010-01-27T20:59:28.700-08:00</updated><title type='text'>Portable MARPOL emissions analyzer - Model 350 Maritime</title><content type='html'>The 350-Maritime is a portable emissions analyser fitted with: O2, CO, CO2-(IR), NO and NO2, gas preparation, integrated rechargeable battery pack and measuring data memory.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;The flue gas sampling is operated via a specially designed gas sampling probe, which can easily be mounted with the help of a flange. The type approved and hard-wearing electro-chemical gas sensors (ECS) record the concentrations of the flue gas components O2, CO and NOx (NO + NO2 separately) highly accurate and longterm stable. CO2 is recorded via a type approved IR-measuring principle. To cope with the rough requirements at sea the entire emission analyzer including accessories is stored in a robust protection case&lt;br /&gt;&lt;br /&gt;The complete kit: - Emission Analyzer 350-MARITIME fitted with: O2, CO, CO2-(IR), NO and NO2, gas preparation, integrated rechargeable battery pack and measuring data memory&lt;br /&gt;Control-Unit 350-MARITIME&lt;br /&gt;&lt;br /&gt;* Connection cable (2 m) between analyzer and Control Unit&lt;br /&gt;* Flue gas sampling probe with probe shaft prefilter&lt;br /&gt;* Mounting flange for gas sampling probe&lt;br /&gt;* Robust protection case with trolley function&lt;br /&gt;* Cable with battery clamps and adapter for connection to 350-MARITIME&lt;br /&gt;* Germanischer Lloyd (GL)-certificate nr. 59 488 - 08 HH&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-5238984854710167238?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/5238984854710167238'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/5238984854710167238'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/12/portable-marpol-emissions-analyzer.html' title='Portable MARPOL emissions analyzer - Model 350 Maritime'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-6857963960350977009</id><published>2010-01-15T17:12:00.000-08:00</published><updated>2010-01-15T17:14:24.292-08:00</updated><title type='text'>X-MET 5000 XRF Analyser</title><content type='html'>Engineered for high performance and reliability, this hand-held XRF analyser combines Oxford Instruments’ patented PentaPIN detector technology offering guaranteed fast analysis and lower limits of detection for all elements of interest.&lt;br /&gt;&lt;br /&gt;X-MET5000 XRF hand-held analyzer is built for the most demanding quality control applications:&lt;br /&gt;&lt;br /&gt;* scrap metal analysis &amp;amp; sorting - analysis of metals for PMI - consumer products for RoHS screening - lead in toys - compliance testing - ore exploration in mining processes - heavy metals monitoring in soils&lt;br /&gt;&lt;br /&gt;Silicon Drift Detector technology improves your productivity saving you money!&lt;br /&gt;&lt;br /&gt;The X-MET5100 combines Oxford Instruments' ground breaking Silicon Drift Detector (SDD) with our own purpose built powerful 45kV X-ray tube. This cutting edge technology delivers a five times faster measurement speed, improved detection limits and significant accuracy improvement over conventional systems.&lt;br /&gt;&lt;br /&gt;This rugged and reliable portable XRF analyzer is IP54 (NEMA 3) approved for superior dust and splash protection.&lt;br /&gt;The X-MET5000 range is perfect for the harshest environments. The battery operating time of one working day is unique and enables extended productivity without returning to base.&lt;br /&gt;&lt;br /&gt;The powerful user programmable software delivers highly accurate results for reliable Go/No-Go decisions.&lt;br /&gt;The X-MET5000 will identify material type and automatically choose the best XRF analysis method.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-6857963960350977009?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6857963960350977009'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6857963960350977009'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2010/01/x-met-5000-xrf-analyser.html' title='X-MET 5000 XRF Analyser'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-8148793300319877918</id><published>2009-12-23T05:41:00.000-08:00</published><updated>2009-12-23T05:43:16.504-08:00</updated><title type='text'>flue gas analyzers</title><content type='html'>AMETEK/Thermox product line offers the greatest selection of flue gas analyzers in the industry. Wether it is an oxygen analyzer, H2S analyzer or moisture analyzer, Ametek has it. Thermox pioneered the use of zirconium oxide with the introduction of our oxygen analyzers in 1967. In 1979, we introduced combined oxygen and combustibles measurement in an overall combustion analyzer.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;AMETEK/Process Instruments provides world class CEM, Moisture and other process analytical measurements.&lt;br /&gt;&lt;br /&gt;Advanced Instruments Inc. is a leading manufacturer of analytical instrumentation specializing in the gas detection measurement of percent, PPM, PPB, and trace levels of oxygen.&lt;br /&gt;&lt;br /&gt;NDC Infrared Engineering has developed an extensive range of on-line near infrared gauges.&lt;br /&gt;&lt;br /&gt;Sick/Maihak offers an extensive range of gas analyzers and analysis systems. Adaptation to different system conditions or solutions of complex measuring tasks - we have the answer: in-situ and extractive measuring technology for installation in complete systems.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-8148793300319877918?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/8148793300319877918'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/8148793300319877918'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/12/flue-gas-analyzers.html' title='flue gas analyzers'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-237747731569630746</id><published>2009-12-03T01:05:00.000-08:00</published><updated>2009-12-03T01:06:44.427-08:00</updated><title type='text'>Gas Analyzer</title><content type='html'>Picarro analyzers are among the world's most sensitive and easy to use real-time gas analyzers for trace detection, many with typical lower detection limits of parts per trillion. In addition to their unprecedented sensitivity, the analyzers operate with no requirement for frequent calibration and with immunity to cross-talk from any other gas component in the sample, including varying moisture levels. These simple to use analyzers can be operated remotely, producing virtually drift-free data over months of operation without calibration. The high dynamic range of these rugged analyzers means they can deliver linear response for concentrations ranging from ppt to % levels, with an absolute accuracy of much less than 1%. Many analyzers offer the ability to simultaneously measure multiple gases in the same low-volume sample cell. This compact cell design minimizes the sample exchange time enabling very fast response times.&lt;br /&gt;&lt;br /&gt;All Picarro analyzers are based on Picarro's unique Wavelength-Scanned Cavity Ring Down Spectroscopy (WS-CRDS), a time-based measurement utilizing a near-infrared laser to measure a spectral signature of the molecule. Gas is circulated in an optical measurement cavity with an effective path length of up to 20 kilometers. A patented, high-precision wavelength monitor makes certain that only the spectral absorption feature of interest is being monitored, greatly reducing the analyzer's sensitivity to interfering gas species, and enabling ultra-trace gas concentration and isotope measurements even if there are other gases present. As a result, the analyzer maintains high linearity, precision, and accuracy over changing environmental conditions with minimal calibration required. Precise temperature and pressure control systems designed into the Picarro analyzers ensure accurate measurements over long periods of time with minimal use of calibration gases. The analyzers are exceptionally rugged, essentially drift and maintenance free, and require no consumables, thereby offering significant ease of use and cost of ownership benefits.&lt;br /&gt;&lt;br /&gt;Easily transportable from site to site, Picarro's analyzers can be set up and running within minutes, and require no absolutely sample preparation or drying. The gas concentration is displayed in real-time with no post-processing required. Designed to operate both in laboratories and in harsh environments, the analyzers can operate for many months without user interaction. The analyzers can be configured to automatically send out measurement data at regular intervals via the Ethernet or optional modem and can output real-time data in digital (via RS-232 interface) and optional analog data formats as well. It is possible to remotely connect with the analyzer's internal Windows-based PC and control it through a standard Remote Desktop connection or with similar remote login software. The analyzer can also use its modem or Ethernet connection to automatically synchronize with an atomic clock time service.&lt;br /&gt;Qualities common to all Picarro analyzers:&lt;br /&gt;&lt;br /&gt;    * Superb sensitivity, precision &amp; accuracy with virtually no drift&lt;br /&gt;    * Fast, continuous, real time measurements without interference&lt;br /&gt;    * Large dynamic range with high linearity&lt;br /&gt;    * Field and laboratory deployable with no consumables&lt;br /&gt;    * Installed and operational in minutes&lt;br /&gt;    * Rugged and insensitive to changes in ambient temperature&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-237747731569630746?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/237747731569630746'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/237747731569630746'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/12/gas-analyzer.html' title='Gas Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-4456527203529648561</id><published>2009-12-02T05:31:00.000-08:00</published><updated>2009-12-02T05:32:22.806-08:00</updated><title type='text'>Hydrogen Fluoride Analyzer</title><content type='html'>LGR’s Hydrogen Fluoride Analyzer (HFA) provides sensitive measurements of HF in ambient air or in industrial process flows with extremely high precision and sensitivity. No longer do you have to spend a lot of money or wait a long time to measure HF with extremely high sensitivity – LGR’s HF Analyzer provides measurements every second with ppbv-level precision. In addition, the HFA can report measurements quickly over a very wide range of HF concentrations. The instrument, based on LGR’s cavity enhanced laser absorption spectroscopy, is extremely simple to use, inexpensive to operate, and includes all components (internal vacuum pump, keyboard, mouse, video monitor) to start recording data within minutes. Other atmospheric gases, including water vapor, carbon dioxide, oxygen, and methane, do not interfere with the HF measurements. The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for unattended long-term operation), and that can send real-time data to a data logger through its analog and digital (RS232 serial) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive. LGR’s Hydrogen Fluoride Analyzer provides the high quality data necessary for the most demanding trace gas monitoring applications.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-4456527203529648561?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/4456527203529648561'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/4456527203529648561'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/12/hydrogen-fluoride-analyzer.html' title='Hydrogen Fluoride Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-3413850886350265571</id><published>2009-11-13T16:29:00.000-08:00</published><updated>2009-11-13T16:32:57.639-08:00</updated><title type='text'>Sniffer Portable Analyzer</title><content type='html'>Sniffer Global Analyzer is the industry's first enterprise-class, plug-and-play network analyzer for wireless and wired networks. Sniffer Global Analyzer gives network managers on-demand network segment monitoring, best-in-class protocol decodes, integrated packet-level expert analysis, and unified wired and wireless management with location-based context – all within a secure environment with true enterprise class control. The unlimited user or 10-user license of this software-based, portable tool provides total worldwide flexibility in deployment across a distributed organization, allowing anytime/anywhere access with no additional licensing costs. Sniffer Global Analyzer is an ideal solution for:&lt;br /&gt;&lt;br /&gt;    * Rapid identification of application and network performance issues over wired and wireless networks&lt;br /&gt;    * Analysis of wired and wireless network links and wireless control infrastructure&lt;br /&gt;    * Analysis of applications and services – in production and prior to roll-out&lt;br /&gt;    * Location of mobile wireless devices on physical map, using integrated Cisco Mobility Services Engine data&lt;br /&gt;    * Second-level security risk assessment&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Unlike every other portable protocol analyzer in the industry, which gives users full, uncontrolled access to network traffic traversing the wire – a potentially huge security problem – Sniffer Global Analyzer contains a unique, centralized, policy-based access that governs how and what a user can manage on the network using the software-based client application. An administrative server controls user access to network data and analyzer functions, monitors activity within the tool, and provides traffic specific charts and views -- eliminating a common and dangerous gap in security at many organizations.&lt;br /&gt;&lt;br /&gt;Sniffer Global Analyzer is the only network analyzer to integrate with Cisco® 3000 Series Mobility Services Engine (MSE). This addresses the daunting challenge of effectively troubleshooting performance issues in a wireless network in which components and problems are constantly in motion and difficult to pinpoint quickly without multiple tools and multiple teams involved. With Sniffer Global Analyzer, users have the ability to connect into the network quickly identify wireless devices and correlate contextual location-based information from Cisco MSE to place these wireless devices on a physical map. Then, Sniffer Global Analyzer users can use the tool to access best-in-class network analysis capabilities to isolate the problem. Faster time-to-knowledge yields optimized performance of the environment and improved user quality of experience.&lt;br /&gt;&lt;br /&gt;Built on the industry’s most advanced and widely deployed Sniffer Portable network analyzer software, Sniffer Global Analyzer contains best-in-class network and application performance troubleshooting functionality. Rich expert modes assist users in quickly identifying errors during packet-level analysis for a wide range of protocol decodes covering all of the most common applications and protocols, including protocols used by VoIP and mobility applications. Sniffer Global Analyzer delivers intuitive, easy-to-use dashboards and network views that include deep packet drill-down capabilities and support for wired 10/100/1000 Ethernet and wireless 802.11 a/b/g/n networks all in one tool -- yielding consistent operation and functionality, reducing desktop tool clutter and greatly accelerating problem resolution.&lt;br /&gt;&lt;br /&gt;Key Benefits&lt;br /&gt;&lt;br /&gt;    * Faster time-to-knowledge for network and application problems&lt;br /&gt;    * Centralized control of tool usage to prevent uncontrolled access to network traffic&lt;br /&gt;    * Enterprise-scale for deployment flexibility&lt;br /&gt;    * Integration with Cisco MSE for location-based troubleshooting in wireless networks&lt;br /&gt;    * Wired and wireless support in a single, scalable tool&lt;br /&gt;    * Best-in-class network and application analysis functionality&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-3413850886350265571?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/3413850886350265571'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/3413850886350265571'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/11/sniffer-portable-analyzer.html' title='Sniffer Portable Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-4855738353957702788</id><published>2009-10-21T07:43:00.000-07:00</published><updated>2009-10-21T07:44:15.720-07:00</updated><title type='text'>Pole-zero analyzer</title><content type='html'>A pole-zero analyzer includes an autocorrelation impulse response calculator, first and second buffers, a pole parameter value table, a first coefficient calculator, a first inverse filter, a second coefficient calculator, a second inverse filter, a pole-zero calculator for calculating a pole parameter and a zero parameter in response to outputs from the first and second inverse filters and calculating an error value for determining the pole parameter, a buffer memory for generating an output from the pole parameter value table obtained when the error value satisfies predetermined conditions and predetermined portions of the zero parameter and the pole parameter calculated by the pole-zero calculator as outputs of the pole-zero analyzer, and a control circuit for controlling operation timings of the respective parts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-4855738353957702788?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/4855738353957702788'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/4855738353957702788'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/10/pole-zero-analyzer.html' title='Pole-zero analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-1078689145708723118</id><published>2009-10-18T10:10:00.000-07:00</published><updated>2009-10-18T10:12:52.099-07:00</updated><title type='text'>RAH-210 Residual Chlorine Monitor &amp; Analyzer</title><content type='html'>Our line of chlorine residual monitors includes Hydro Instruments' ampermetric analyzer. The Series RAH-210 Analyzer determines residual chemical levels in the sample water. The measurement cell consists of large Copper and Gold electrodes in direct contact with the sample water. This reagent-free analyzer is continuous and does not rely on older "sample and hold" methods thus it provides a much improved process control.&lt;br /&gt;&lt;span style="font-size:85%;color:#ff0000;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:85%;color:#ff0000;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:85%;color:#ff0000;"&gt;Note: Food-grade vinegar can be used as the pH buffer reagent if the water pH varies. If pH is relatively constant and you are measuring free chlorine, no buffer solution is required.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Main Features:&lt;br /&gt;&lt;/strong&gt;• Measures free, or total chlorine&lt;br /&gt;• Detects Chlorine Dioxide levels&lt;br /&gt;• Monitors Bromine and Iodine&lt;br /&gt;• pH and Temperature Compensation&lt;br /&gt;• Uses food grade vinegar for buffer solution&lt;br /&gt;• Optional PH probe compensation available&lt;br /&gt;• Continuous measurement meter&lt;br /&gt;• Standard PID controller set point residual&lt;br /&gt;• Continuous sensor cleaning mechanism&lt;br /&gt;• Adjustable measurement range&lt;br /&gt;• Alarm contact relay for signal loss&lt;br /&gt;• Two loop powered 4-20 mA inputs and one&lt;br /&gt;4-20 mA output&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Maintenance:&lt;br /&gt;&lt;/strong&gt;A continuously driven cleaning system is employed to prevent a concentration of impurities on the surface of the electrodes which reduces the need for maintenance.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-1078689145708723118?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/1078689145708723118'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/1078689145708723118'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/10/rah-210-residual-chlorine-monitor.html' title='RAH-210 Residual Chlorine Monitor &amp; Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-6006903552789721094</id><published>2009-10-15T18:49:00.000-07:00</published><updated>2009-10-15T18:50:53.746-07:00</updated><title type='text'>Ultra-Portable, USB-Powered Real-Time Analyzer</title><content type='html'>&lt;a href="http://4.bp.blogspot.com/_wJJTWDOWeLE/StfRWTbJQoI/AAAAAAAAAEM/UG18A-4oH8k/s1600-h/usb_small_lightblue.jpg"&gt;&lt;img style="MARGIN: 0px 10px 10px 0px; WIDTH: 207px; FLOAT: left; HEIGHT: 171px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5393009259900912258" border="0" alt="" src="http://4.bp.blogspot.com/_wJJTWDOWeLE/StfRWTbJQoI/AAAAAAAAAEM/UG18A-4oH8k/s320/usb_small_lightblue.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Equipped with a 24-bit four-channel USB powered dynamic acquisition module, the SO Analyzer USB4 is the perfect engineering tool for portable noise and vibration applications. It provides highly accurate measurements from audio frequency IEPE (ICP) sensors and all the functionality you need for your daily test job at a surprisingly low price.&lt;br /&gt;&lt;br /&gt;Thanks to its self-powered USB 2.0 hi-speed connectivity to a host PC or a laptop, the SO Analyzer is a compact real-time analyzer designed for professional applications in the field and in the laboratory. Measurements have never been so easy: Load the SO software, connect the USB cable between the acquisition module and the host PC/laptop and start your measurement using ICP® sensors powered direct from the USB front-end. With 25 kHz bandwidth, 24-bit resolution and 102 dB dynamic range, the SO Analyzer offers very high precision on four channels and upwards and is perfectly suited for versatile N&amp;amp;V measurements and analyses.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-6006903552789721094?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6006903552789721094'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6006903552789721094'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/10/ultra-portable-usb-powered-real-time.html' title='Ultra-Portable, USB-Powered Real-Time Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_wJJTWDOWeLE/StfRWTbJQoI/AAAAAAAAAEM/UG18A-4oH8k/s72-c/usb_small_lightblue.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-2950658840234734379</id><published>2009-10-14T00:31:00.000-07:00</published><updated>2009-10-14T00:32:22.306-07:00</updated><title type='text'>Heat analyzer</title><content type='html'>A heat analyzer equipped to automatically perform operations necessary for protection of measured data and for restart when a problem occurs or a measurement ends and to quickly turn off all power sources by a command input manually by an operator to a system section after daily use. At least one measurement-section power source 6 which can be turned off by an associated measurement controller 5 and a system-section power source 14 which can be turned off by a system controller 11 are included. When the temperature program of every measurement controller 5 connected to the system controller 11 through data transmission paths 8a to 8c is executed, an external environment sensor 9 detects a problem, or the operator issues a command, the system controller 11 transfers information from volatile memory 10 to a nonvolatile memory 13 before commanding every measurement controller 5 to turn off the measurement-section power source 6 and providing the system-section power source 14 with a control for turning off the system-section power source.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-2950658840234734379?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/2950658840234734379'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/2950658840234734379'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/10/heat-analyzer.html' title='Heat analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-6742176798804612328</id><published>2009-10-09T21:00:00.000-07:00</published><updated>2009-10-09T21:04:29.550-07:00</updated><title type='text'>Exhaust gas analyzer</title><content type='html'>&lt;p&gt;&lt;/p&gt;&lt;p&gt;CN61M/M311048-type exhaust gas analyzer (five copies)&lt;br /&gt;Measuring range:&lt;br /&gt;Used to measure vehicle emissions in gasoline engines&lt;br /&gt;The HC, CO, CO2, O2, and NO gas concentrations.&lt;br /&gt;Full Chinese menu operation, LCD liquid crystal screen display,&lt;br /&gt;In auto-zeroing, automatic calculation and display the air-fuel ratio&lt;br /&gt;λ. Can be the engine combustion performance and emissions from sewage&lt;br /&gt;Conduct a comprehensive inspection dye. The instrument uses the country&lt;br /&gt;Foreign advanced technology, import the key components and sensors:&lt;br /&gt;Assembled. With a time display function, with 800&lt;br /&gt;Group registration number of input data storage and search functions.&lt;br /&gt;Equipped with RS-232C serial digital communication interface.&lt;br /&gt;Optional external printer for data printing, standard sense of&lt;br /&gt;Ying-type speed measurement pliers, options with oil temperature probe attachment&lt;br /&gt;To Idle or dual idle measurement.&lt;br /&gt;&lt;br /&gt;HC: 0 ~ 10,000 × 10-6ppm vol&lt;br /&gt;CO: 0 ~ 10 × 10-2% vol&lt;br /&gt;CO2: 0 ~ 18 × 10-2% vol&lt;br /&gt;O2: 0 ~ 23 × 10-2% vol&lt;br /&gt;NO: 0 ~ 5,000 × 10-6 ppm vol&lt;br /&gt;&lt;/p&gt;&lt;p&gt; &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-6742176798804612328?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6742176798804612328'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6742176798804612328'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/10/exhaust-gas-analyzer.html' title='Exhaust gas analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-21882865475964691</id><published>2009-10-01T18:23:00.000-07:00</published><updated>2009-10-01T18:26:31.327-07:00</updated><title type='text'>Nitrogen Oxides (NOx) Analyzer</title><content type='html'>The Model 200AH High Range NO/NO2/NOX Analyzer uses the field-proven chemiluminescent technique for monitoring high levels of oxides of nitrogen. User-selectable ranges of 5 ppm to 5000 ppm make it ideal for a wide variety of applications including CEM, stack testing, and process control. A choice of NO2-to-NO converters handles tough CEM and stack testing applications. Selectable measurement modes (NO only, NOx only, NO/NOx switching), auto ranging and remote range control let you set up the Model 200AH to your exact needs. The modular design offers top-mounted access to all subassemblies and has hinged front and rear panels to simplify module replacement. The modular, sealed ozone generator provides improved voltage coefficient, safety, and reliability. A standard permeation dryer on the ozone generator means there is no desiccant to replace. In addition, the excess ozone is removed by catalytic reaction, eliminating the need for charcoal (expendable) replacement.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-21882865475964691?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/21882865475964691'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/21882865475964691'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/10/nitrogen-oxides-nox-analyzer.html' title='Nitrogen Oxides (NOx) Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-2492383785174689789</id><published>2009-09-23T17:15:00.000-07:00</published><updated>2009-09-23T17:16:15.640-07:00</updated><title type='text'>Ambient Level Multi-Gas Analyzer</title><content type='html'>The Cerex HOUND series are portable multi-gas analyzers developed to detect part per billion (ppb) to percent level concentrations of multiple gases within a mixture. The HOUND produces laboratory quality results in real-time using ultraviolet light absorption - similar to traditional infrared detectors, but features lower detection limits on many human health hazards and does not interfere with water vapor. All HOUND series analyzers come standard in a weather-resistant case with an integrated display, active ambient air sampling, and wireless communication. The FR versions are well suited for smoky or dusty environments with a faster sample rate and replaceable glass fiber sub-micron sample filter.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-2492383785174689789?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/2492383785174689789'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/2492383785174689789'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/09/ambient-level-multi-gas-analyzer.html' title='Ambient Level Multi-Gas Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-6017263177174137473</id><published>2009-09-23T17:13:00.000-07:00</published><updated>2009-09-23T17:14:44.641-07:00</updated><title type='text'>hermo Fisher Scientific Model 42iHL - NO-NO2-NOx Analyzer</title><content type='html'>This NOx monitor by Thermo Environmental generates three continuous signals: NO, NO2 and NOx. All three ranges are independent and have available outputs at the back of the analyzer. Meets USEPA requirements for RFNA-1289-074. The i series of analyzers also allows for ethernet connections. The Thermo 42i-HL can function as a datalogger and has enhanced diagnostics over its predecessors. The 42iHL also has dual range capabilities.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-6017263177174137473?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6017263177174137473'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/6017263177174137473'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/09/hermo-fisher-scientific-model-42ihl-no.html' title='hermo Fisher Scientific Model 42iHL - NO-NO2-NOx Analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-3223706315418806273.post-9177762028755969221</id><published>2009-09-23T17:08:00.000-07:00</published><updated>2009-09-23T17:11:02.624-07:00</updated><title type='text'>NOx analyzer</title><content type='html'>NO, NO2 and O2 on the inlet to an SCR.&lt;br /&gt;&lt;br /&gt;NOx and O2 on the inlet to an SCR.&lt;br /&gt;&lt;br /&gt;The gas stream contains ammonia, nitrogen oxides and in some cases sulfur dioxide . The NOx analyzer is a UV diode array process analyzer. Measuring the complete spectrum of the stream continuously and instantaneously.&lt;br /&gt;&lt;br /&gt;The full spectrum advantage&lt;br /&gt;The figures below show the absorbance spectra of the DeNOx process stream components,. The absorbance features overlap, therefore, a full high resolution spectral analysis is essential. High accuracies at a relatively wide dynamic range can be achieved due to the sharp absorbance features of the DeNOx stream component&lt;br /&gt;&lt;br /&gt;The system uses an aspirator driven extractive sampling system with a heated umbilical sample line. The sample flows through the absorption cell and the oxygen sensor in series. Long sample lines are avoided, minimizing the normal sample losses associated with sample adhesion to interior tubing walls.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3223706315418806273-9177762028755969221?l=global-analyzer.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/9177762028755969221'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3223706315418806273/posts/default/9177762028755969221'/><link rel='alternate' type='text/html' href='http://global-analyzer.blogspot.com/2009/09/nox-analyzer.html' title='NOx analyzer'/><author><name>dimple</name><uri>http://www.blogger.com/profile/15055230123795503830</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry></feed>
